Introduction
AF9900/100K is a centralized bypass 3 phase input and 3 phase output modular UPS. The product adopts digital control, modular design and N+X parallel redundancy technology. The product capacity covers various power ranges from 100kVA to 600kVA, which is convenient for users to flexibly configure and gradually invest. 4 units can be connected in parallel to 2400kVA.
Application
This product has a wide range of applications, providing safe, stable, reliable and environmentally friendly power supply for key loads such as data centers, financial centers, government and enterprise computer rooms, medical education, etc.
Feature
Advanced technology
●Adopt digital control, excellent performance, high system stability, and can connect to completely unbalanced loads.
●Adopting advanced three-phase Vienna and three-level technology, the overall efficiency is as high as 97%.
●The output power factor is 1.
High reliability
●The centralized control unit is redundant in parallel, and the failure of one will not affect the operation of the entire machine. The N+X parallel redundancy availability reaches 99.999%.
●The centralized monitoring module has hot-swap function and adopts centralized bypass power supply to improve the power supply capacity of bypass power supply.
●With EPO function and remote emergency power off(REPO) function.
Convenient and flexible
●Modular design, users can flexibly increase the number of modules, and modules can be added and removed online.
●Short downtime for maintenance. When an emergency occurs on the UPS, maintenance personnel can safely perform maintenance online.
●Touch color screen display, providing rich UPS status information, warning information, fault information, etc.
Intelligent design
●The battery capacity and charging current can be set on the LCD screen to achieve automatic and smooth transferring of charging modes.
●Adopts advanced two-stage three-stage intelligent charging, which takes into account both fast charging and extended battery life.
● Rich optional accessories, you can choose to install isolation transformer, SNMP card, dry contact card, etc.
Green and Environmentally Friendly
●Adopt 3U module design, which perfectly matches the application environment of the computer room and saves the use area of the computer room.
●Parallel systems share the same battery, greatly reducing the number of batteries required.
●30-50 external batteries are optional, no battery neutral wire is required, which is convenient for users to flexibly configure batteries.
Model | AF99600/100K | |
Capacity | Cabinet | 100~600kW |
Modules | 100kW | |
Maximum Modules in the Cabinet | 6 | |
Enter | ||
Main Input | Rated Input Voltage | 380/400/415Vac |
Input Voltage Regulation | 138 ~ 485Vac | |
Phase | Three-phase five-wire | |
Input frequency Range | 40-70Hz | |
Input Power Factor | ≥0.99 | |
Input Current harmonics (THDi) | ≤3% (100% linear load ) | |
Bypass Input | Rated Input Voltage | 380/400/415Vac |
Phase | Three-phase five-wire | |
Bypass Synchronous Tracking Range | ±10% | |
Output | ||
Voltage | 380/400/415Vac±1% | |
Power Factor | 1 | |
Frequency (Hz) | Mains Mode | Tracking bypass (inverter power supply) |
Battery Mode | (50/60±0.05%)Hz | |
Waveform | Sine Wave | |
Current Peak Ratio | 3:1 | |
Output Voltage Harmonics (THDV) | ≤ 1% (100% linear load ) ; ≤ 3% (100% non-linear load ) | |
Transferring Time | AC mode to bypass mode: 0ms (tracking); AC mode to battery mode: 0ms | |
Overall Efficiency (%) | 97% | |
Overload Capacity | 110% load, switch to bypass after 60 minutes ; 125% load, switch to bypass after 10 minutes ; 150% load, switch to bypass after 1 minute | |
Battery | ||
Module Maximum Charging Current | 30A | |
Battery Voltage | Optional voltage : 360-600Vdc (30~50 cells optional), battery without neutral line | |
Environment | ||
Operating Temperature | 0℃ ~ 40℃ | |
Storage Temperature | -40 ℃ ~ 70 ℃ (without battery) | |
Humidity | 0 ~ 95% (non-condensing) | |
Altitude | < 1500m (if it exceeds 1500m, the rated value shall be derated according to GB/T 3859.2 ) | |
Noise | <70dB | |
Other Features | ||
Alarm Function | Multiple alarm functions such as overload, AC power abnormality, UPS failure, battery undervoltage, etc. | |
Protection Function | Short circuit, overload, over temperature, battery undervoltage, output overvoltage and undervoltage, fan failure alarm, lightning protection, bypass backflow | |
Communication Function | CAN , RS485 , network interface, dry contact, parallel interface, LBS interface, smart slot, temperature sensor interface | |
Mechanical Properties | ||
Dimensions (D×W×H)(mm) | Cabinet/Module | 1000×800×2000/750×440×130 |
Net weight (kg) | Cabinet/Module | 412/49 |
Provide customers with quality products and services. If you have any questions about our products, feel free to call or email us.
Please fill in the form and attach your detailed information so that we can understand your requirements regarding power supply.
One of our experts will contact you to discuss the most effective solution and the expected delivery time.
You will be presented with a detailed quote and exact time-frames.
If you have any suggestions or questions, Please free to contact us.
Next: None