AF8300 series Online Transformer-Based Fully Digital UPS is a highly intelligent product integrating digitization, informationization and networking, with a powerful information collection system, signal processing system, detection system and perfect protection system. It is widely used in various power consumption environments, with customized design, powerful interact function, intuitive display screen and status indication monitoring interface, making it very simple and convenient for users to operate and use.
Application
Finance, communications, insurance, transportation, taxation, military, securities, energy, education, government, manufacturing, enterprises, computer equipment, precision instruments and equipment, etc.
Feature
Design concept for China's power grid environment to improve system availability
●3 phase input and single phase output 380V/220V, ultra-wide AC input voltage range, suitable for China power grid;
●The ultra-wide input frequency range ensures that all kinds of fuel generators can work stably;
Highly reliable design concept to ensure stable operation of the network system
●Pure online double conversion topology design provides high-quality power quality;
●Use SPWM pulse width modulation, IGBT power module and output isolation transformer to ensure that UPS output is not affected by power grid fluctuations and noise;
●Adopt advanced phase-locked synchronization technology and electronic static bypass switch, output zero switching time, meet the high standard requirements of precision equipment for power supply, and ensure the continuity of load power supply;
●Based on advanced microprocessor control technology, comprehensively improve the availability and reliability of the system;
●UPS inverter and PFC adopt advanced full digital control technology, input power factor greater than 0.98 and very low harmonic current; (optional)
●When there is no AC power, the UPS can be started directly with the battery, or directly with the AC power without a battery. After the battery is discharged to undervoltage protection, the UPS will automatically start after the AC power is restored.
Intelligent battery management technology effectively extends the battery life
●Intelligent battery management technology, automatic conversion between equalization charge and floating charge, can effectively extend the battery life;
●Autonomous current-sharing high-power charger that can be connected in parallel, with current-sharing imbalance ≤3%, effectively shortening charging time and meeting system configuration requirements.
Perfect protection function greatly ensures the stability and reliability of the system
●It has super cold start capability and can perform cold start operation under full load to meet the emergency needs of users;
●It has intelligent unattended function to meet the needs of special occasions;
●With the function of power-on self-diagnosis, the UPS fault hidden dangers can be discovered in time to avoid the risk of failure caused by potential hidden dangers;
●It has multiple protection functions including input surge protection, output overload/short circuit protection, battery failure and low voltage warning protection, battery overcharge protection, inverter over-temperature and fault-to-bypass power supply protection, etc., which ensures the stability and reliability of system operation.
Advanced digital parallel control technology
●Digital circulating current control technology ensures that the UPS in parallel have the same frequency, phase and voltage, greatly reducing the circulating current between parallel UPS and comprehensively improving the reliability of the parallel system;
●UPS with different powers can be connected in parallel, and the load can be automatically distributed according to the UPS power, which greatly facilitates the expansion of UPS;
●Closed-loop redundant parallel communication cable comprehensively improves the safety and reliability of parallel operation;
●Parallel UPS can share the same battery pack, saving investment.
User friendly interface LCD+LED and network management function
●With multiple sound and light warning functions, concise and clear;
●LCD display interface provides accurate UPS operating parameters and working conditions;
●Through the RS232 interface, with the UPS intelligent monitoring software, it can communicate with the PC in real time. The various parameters and working status of the UPS system are clearly displayed on the communication interface of the PC. Through settings, the computer can directly control various functions of the UPS system;
●With optional functions of RS485 interface and DB9 dry node interface;
●An external SNMP adapter can be installed. The system has a direct Internet access function, providing real-time UPS data and power information.
A network management platform is used for communication and management, and the system immediately becomes a member of the network.
Capacity | 10KVA | 15KVA | 20KVA | 30KVA |
AC Input | ||||
Rated Voltage | 380V±25% | |||
Frequency | 50Hz/60Hz±10% | |||
Phase | Three-phase four-wire system | |||
Maximum Current | 56 | 84 | 112 | 168 |
AC Output | ||||
Rated Voltage | 220V±1% | |||
Frequency | 50Hz/60Hz±0.5% | |||
Power Factor | 0.9-1 | |||
Waveform | SPWM pure ripple | |||
Waveform Distortion | Linear load: <3%; | |||
Overload Capacity | Overload 120% can last for 10 minutes; overload 150% can last for 20 seconds | |||
Transient Response | Voltage change ≤4% (100% load switched on or off) | |||
Overall efficiency | >85% | |||
Transferring Time | 0ms | |||
Battery | ||||
Rated voltage | 192VDC | |||
Battery Type | 12V sealed maintenance-free battery | |||
Charging time | 90% capacity completed within 8-10 hours | |||
Warning | ||||
Utility power outage | The buzzer sounds every 4 seconds | |||
Low Battery | The buzzer beeps every 1 second | |||
Overload | The load indicator light is on. The buzzer beeps continuously. | |||
Inverter Abnormality | The fault indicator light is on and the buzzer beeps continuously. | |||
Internal Protection Device | ||||
Battery | Automatic shutdown when battery is low, no fuse switch protection | |||
Overload | Overload (110-150%) will automatically switch to bypass after 30 seconds. Automatic recovery | |||
Over Temperature | Inverter internal temperature>85C. Automatically switch to bypass | |||
Output Short Circuit | Current limiting, automatic shutdown fuse and fuseless switch protection | |||
Inverter Abnormality | Automatically switch to bypass and supply power from AC power | |||
Noise | 10~100KHz at 40dB; 100KHz~100MHz at 70dB | |||
Interface | ||||
LCD Display | Input and output voltage, frequency, battery voltage, load power, internal temperature, working status, etc. | |||
LED Indicator Light | Indications for AC, inverter, bypass, battery, overload, abnormality, etc. | |||
Environment | ||||
Operating Temperature | 0-40℃ | |||
Humidity | 20% - 90%, no condensation | |||
Altitude | <1500m | |||
Physical Properties | ||||
Wiring Method | Terminal Blocks | |||
Net Weight Kg | 199 | 220 | 305 | 380 |
Size Width × Depth × Height (mm) | 410*710*1055 |
Provide customers with quality products and services. If you have any questions about our products, feel free to call or email us.
Please fill in the form and attach your detailed information so that we can understand your requirements regarding power supply.
One of our experts will contact you to discuss the most effective solution and the expected delivery time.
You will be presented with a detailed quote and exact time-frames.
If you have any suggestions or questions, Please free to contact us.